2.1.1.10.6

Parameter Data Sets

2.1.1.10.6.1

Available Parameter Data Sets

The module provides three different parameter data sets.
Factory Default
Fig. 2.1.1-30: Parameter data sets 1...3
The parameter data sets have the following functions:
Data set
number
2.1.1.10.6.1.1

Actual (1)

The Actual (1) parameter data set contains the parameters the module uses.
The parameter data set Actual (1) is copied 1:1 from the parameter data set
User Settings (2) upon module system start; i.e., after power-up or after a
module reset.
2.1.1.10.6.1.2

User Settings (2)

The parameter data set User Settings (2) offers the user the possibility to
permanently store runtime parameters in the module and to reload them, if
necessary.
WAGO-I/O-SYSTEM 750
I/O-Modules
Configuration of the I/O Module via the Parameter Channel
Actual
(1)
User Settings
(2)
(3)
Description
1
Actual
2
User Settings
3
Factory Default
750-636 [DC Drive Controller]
Description
Current parameters used by the module
Custom-specific parameter settings
Manufacturer-specific parameter settings
• 59