750-636 [DC Drive Controller]
Process Image
Reg_Com
Switch
PresetInput
_Enabled
Optimize_On
ExtendedInfo
_On
PWM_Active
CurrentControl
_ON
PresetInput
LimitSwitch_
Pos
LimitSwitch_
Neg
Register communication (see section 2.1.1.10.4).
0:
Process data communication enabled.
1:
Register communication enabled.
Bit 7
Bit 6
Bit 5
Limit
Limit
Preset
Switch
Input
_Neg
_Pos
This bit indicates that the preset input is enabled.
0:
Preset input is not enabled.
1:
Preset input is enabled.
This bit indicates prestop optimization during the positioning process.
0:
Prestop is not optimized.
1:
Prestop is optimized.
This bit indicates that the data in the input process image (byte 2 to 5)
was changed.
0:
Extended status information disabled.
1:
Extended status information enabled.
This bit indicates if the DC Drive Controller has generated a PWM
signal at the motor output.
0:
No PWM signal at the motor output.
1:
PWM signal at the motor output.
This bit indicates if the motor final stage is operated with
CurrentControl_PWM.
0:
Motor final stage is not operated with CurrentControl_PWM.
1:
Motor final stage is operated with CurrentControl_PWM.
This bit indicates the input status of the preset switch.
0:
Signal voltage (0) at the input.
1:
Signal voltage (1) at the input.
This bit indicates the input status of the positive limit switch.
0:
Signal voltage (0) at the input.
1:
Signal voltage (1) at the input.
This bit indicates the input status of the negative limit switch.
0:
Signal voltage (0) at the input.
1:
Signal voltage (1) at the input.
Status byte S1
Bit 4
Bit 3
Bit 2
Current
PWM_
Extended
Control
Active
Info_On
_ON
Bit 1
Bit 0
Optimize
Preset
_On
Input
_Enabled
WAGO-I/O-SYSTEM 750
I/O-Modules