2.1.1.10.2.9

Filter_Time

Parameter
address
Filter_Time
Debounce time of the digital inputs with n times 3ms.
Bit 0...3: Debounce time digital input E+ [0...15]
0:
1...15:
10:*
Bit 4...7: Debounce time digital input E- [0...15]
0:
1...15:
10:*
Bit 8...11: Debounce time digital input P [0...15]
0:
1...15:
10:*
Bit 12...15: Reserved
* factory setting
WAGO-I/O-SYSTEM 750
I/O-Modules
Configuration of the I/O Module via the Parameter Channel
Function
9
Filter_Time
No software debouncing
Debounce time of 3 ms to 45 ms
Default debounce time 30 ms
No software debouncing
Debounce time of 3 ms to 45 ms
Default debounce time 30 ms
No software debouncing
Debounce time of 3 ms to 45 ms
Default debounce time 30 ms
750-636 [DC Drive Controller]
Access
Factory setting
R/W
• 49
0xAAAA