Example 20, "Approach with CurrentControl_PWM =
f(CurrentControl_ON), Version 2":
100 %
Fig. 2.1.1-27: Example 19, "Approach with CurrentControl_PWM = f(CurrentControl_ON),
Version 2"
CurrentControl_ON=1 is already set during phase P2. Phase P2 must not be
interrupted prematurely, just as shown in the example figure 3 10
(ShutDown_Distance in P2). Using CurrentControl_ON, it is possible to start
phase P3 with CurrentControl_PWM after the elapse of CurrentLimit_Time.
Please note that the PWM can be set to 100 % by resetting
CurrentControl_ON during phase P3.
WAGO-I/O-SYSTEM 750
I/O-Modules
P1
CurrentLimit_PWM
50 %
0 %
RampTime_START
CurrentLimit_Time
Control.CurrentControl_ON = 0
g063629e
750-636 [DC Drive Controller]
P2
P3
CurrentControl_PWM
Control.Current-
Control_ON = 0
Function Description
P5
Set Point Position
PWM 100 %
RampTime_STOP
Control.CurrentControl_ON = 0
• 39