Ricoh B064 SERIES Service Manual page 1392

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

BIT SWITCHES
Communication Switch 14 [SP No. 1-104-021]
No
FUNCTION
Inch-to-mm conversion during
0
transmission
0: Disabled 1: Enabled
1-5 Not used
Available unit of resolution in
which fax messages are
received
Bit 7: 0, Bit 6: 0 = mm
6-7
Bit 7: 0, Bit 6: 1 = inch
Bit 7: 1, Bit 6: 0 = mm and
inch (default)
Bit 7: 1, Bit 6: 1 = Not used
Communication Switch 15 – Not used (do not change the settings)
Communication Switch 16 [SP No. 1-104-023]
No
FUNCTION
0
Not used
Optional G3 unit (G3-2)
1
0: Off
1: On
2
Not used
Optional G3 unit (G3-3)
3
0: Off
1: On
4-7 Not used
B819/B820
CÓPIA NÃO CONTROLADA
0: In immediate transmission, data scanned in
inch format are transmitted without conversion.
In memory transmission, data stored in the SAF
memory in mm format are transmitted without
conversion.
NOTE: When storing the scanned data into SAF
memory, the fax unit always converts the
data into mm format.
1: The machine converts the scanned data or
stored data in the SAF memory to the format
which was specified in the set-up protocol
(DIS/NSF) before transmission.
Do not change the factory settings.
For the best performance, do not change the
factory settings.
The setting determined by these bits is informed
to the transmitting terminal in the pre-message
protocol exchange (in the DIS/NSF frames).
Do not change the factory settings.
Change this bit to "1" when installing the first
optional G3 unit (G3-2).
Do not change the factory settings.
Change this bit to "1" when installing the second
optional G3 unit (G3-3).
Do not change the factory settings.
82
CÓPIA NÃO CONTROLADA
COMMENTS
COMMENTS
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B246 seriesB140 seriesD052 series

Table of Contents