BIT SWITCHES
System Switch 13 - Not used (do not change these settings)
System Switch 14 - Not used (do not change these settings)
System Switch 15 [SP No. 1-101-022]
No
FUNCTION
0
Not used
Going into the Energy Saver
mode automatically
1
0: Enabled
1: Disabled
2-3 Not used
Interval for preventing the
machine from entering Energy
Saver mode if there is a
pending transmission file.
Bit 5: 0, Bit 4: 0
1 min
4-5
Bit 5: 0, Bit 4: 1
30 min1
Bit 5: 1, Bit 4: 0
1 hour
Bit 5: 1, Bit 4: 1
24 hours
6-7 Not used
System Switch 16 [SP No. 1-101-023]
No
FUNCTION
Parallel Broadcasting
0
0: Disabled
1: Enabled
Priority setting for the G3 line.
1
0: PSTN-1 > PSTN-2 or 3
1: PSTN-2 or 3 > PSTN-1
2-7 Not used
System Switch 17 - Not used (do not change these settings)
System Switch 18 - Not used (do not change these settings)
B819/B820
CÓPIA NÃO CONTROLADA
Do not change the settings.
1: The machine will restart from the Energy Saver
mode quickly, because the +5V power supply is
active even in the Energy Saver mode.
Do not change these settings.
If there is a file waiting for transmission, the
machine does not go to Energy Saver mode
during the selected period.
After transmitting the file, if there is no file waiting
for transmission, the machine goes to the Energy
Saver mode.
Do not change
1: The machine sends messages simultaneously
using all available ports during broadcasting.
This function allows the user to select the default
G3 line type. The optional SG3 unit(s) are
required to use the PSTN-2 or 3 setting.
Do not change these settings.
60