Plc Status - Siemens SINUMERIK 840D Operator's Manual

Hmi advanced
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

8
"Diagnosis" Operating Area

8.4 PLC status

8.4
PLC status
8.4.1 General
Inputs:
Outputs:
Bit memories:
Timers:
Counters:
Data:
Format:
8-424
Function
You can obtain information about the current states of the following
memory locations of the PLC and change them if necessary:
Input bit (Ex), input byte (EBx)
Input word (Ewx), input double word (Edx)
Output bit (Ax), output byte (Abx)
Output word (Awx), output double word (Adx)
Memory bit (Mx), memory byte (MBx)
Memory word (MWx), memory double word (MDx)
Time (Tx)
Counter (Cx)
Data block (DBx), data bit (DBxx), data byte (DBBx),
data word (DBWx), data double word (DBDx)
B = binary
H = hexadecimal
D = decimal
G = floating comma (for doublewords)
Operand
Example
Condition
Inputs
Yes
I 2.0
IB 2
Outputs
Yes
Q20.1
QB 20
Markers
Yes
M 60.7
MB 60
MW 60
Timers
T20
Yes
SINUMERIK 840D/840Di/810D Operator's Guide HMI Advanced (BAD) – 03.04 Edition
Writing
Format Value
Yes
B
0
B
0101 1010
H
5A
D
90
Yes
B
1
B
1101 0110
H
D6
D
214
Yes
B
1
B
1101 0110
H
B8
D
180
no
B
H
D
Ó Siemens AG, 2004. All rights reserved
8
03.04
Range
0-127
0-127
0-255
0-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840diSinumerik 810d