Example Layouts - Bosch DCN Next Generation Installation & User's Instructions

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | System Design and Planning
2.6.5
Bending
The minimum bend radius of a 90 degree bend in an
LBB4416 cable is 110 mm (refer to figure 2.3). A
180 degree bend is the same as two 90 degree bends.
R=110 mm
figure 2.3: Bend radius
2.6.6
Coiling
The minimum coiling radius of an LBB4416 cable is
110 mm (refer to figure 2.4).
figure 2.4: Coiling radius
Bosch Security Systems | 2007-02 | 9922 141 70525
R=110 mm
2.7

Example layouts

2.7.1
Introduction
The number and type of devices that make the optical
network give the layout of the optical network. This
chapter shows examples of the possible layouts of
optical networks.
2.7.2
Basic optical network
Refer to figure 2.5 for an example of a basic optical
network.
LBB4404/00
PRS-4DEX4
figure 2.5: Basic optical network
en | 26
DCN-CCU
LBB4402/00
INT-TX