table 8.31: Setup sub-menu (* = default)
Menu item
7A Mic. Priority
7B Att. Tones
7C Request LED
7D Floor Distr.
7E Intercom ...
7F Del. Display
7G Routing I/O 2
7H Level
7I Multi mode
7J De-Init ...
7K Unit Name
7L Defaults ...
Bosch Security Systems | 2007-02 | 9922 141 70525
Parameter
Value
---
Temporarily off*
Permanently off
Event:
Chime:
Priority*
Off, 1*, 2, 3
Voting
Off*, 1, 2, 3
LED setting
Flashing*, Continuous
---
On*, Off
---
---
---
Language:
English*
German
French
Italian
Dutch
Spanish
---
Single mode:
Recorder*
Delegate loudspeaker
Mix-minus
Insertion
Multi-mode:
Recorder*
Delegate loudspeaker
Local floor
Signal:
Level:
Input 1
-6 to 6 dB (0 dB*)
Input 2
-6 to 6 dB (0 dB*)
Output 1
-24 to 6 dB (0 dB*)
Output 2
-24 to 6 dB (0 dB*)
Mode:
Multi CCU slave ID
Single*
--*, 01 to 30
Multi
---
---
---
Name:
CCU*
Custom name
---
---
Description
The action taken by the system when the
chairman releases the priority button (refer
to section 8.8.4).
The attention chimes of the system (refer to
section 8.8.3).
Sets the behaviour of the request LED for
the first delegate in the request list.
Enables or disables floor distribution (refer
to section 8.8.5).
Gives access to the Intercom sub-menu
(refer to section 8. 1 0. 1 2).
The language that is used by the displays of
the contribution devices. Other languages
(e.g. Chinese) can be downloaded to the
CCU, but will overwrite the default
languages. The English language cannot be
overwritten.
The audio routing mode of the central
control unit (refer to section 8.8.2).
The nominal levels of the audio inputs and
the audio outputs of the central control unit.
Sets the CCU to single or multi mode. The
multi CCU slave ID can only be changed
when the unit is in single mode (refer to
section 10.7).
Gives access to the De-initialization menu
item (refer to section 8. 1 0. 1 3).
The name of the central control unit (max. 16
characters).
Gives access to the Reset menu item (refer
to section 8. 1 0. 1 4)
en | 70