42.3 Installation

Refer to section 41.4 for information about the
installation of the fiber interface. The procedures to
install the network splitter and the fiber interface are the
same.

42.4 External connections

42.4.1 Optical network
The fiber interfaces connects a POF to a GOF. Use a
GOF to connect two pieces of equipment in the optical
network that are more than 50 m apart and less than
1,500 m. Use the fiber interfaces as a pair. The first
connects a POF to a GOF, the second connects the
GOF to a POF (refer to figure 42.2).
POF
2
5
GOF ( > 50m)
figure 42.2: Optical network
Note
If the distance between two devices is less than
100 m, a network splitter can be used in the
middle to remove the use of fiber interfaces. Use
only the trunk sockets of the network splitter in
this case.
Bosch Security Systems | 2007-02 | 9922 141 70525
The GOF socket is a double SC socket (refer to figure
42.3) that uses invisible infra-red light (1300 nm).
Refer to figure 42.4 for an example of a GOF cable with
POF
a double SC plug.
2
5
Make sure that all GOF cables:
Tx
figure 42.3: Double SC socket, connection
table 42. 1 : Double SC socket, connection
Pin
Tx
Rx
figure 42.4: GOF with double SC plug
Are multi-mode GOF cables. (The system cannot use
single mode GOF cables.)
Are applicable for light with a wavelength of
1300 nm.
Have a maximum attenuation of 2 dB/km.
table 42.2: Optical network connections
Number of connections:
1x optical network socket (POF)
1x optical network socket (GOF)
Location:
Front and rear sides
Power consumption:
4.6 W