Environmental Conditions; Safety - Bosch DCN Next Generation Installation & User's Instructions

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | System Design and Planning
7.1.3
Combined devices from input to
output
Delegate microphone with transmission link to
interpreter headphones
Delegate microphone with transmission link to
delegate headphones
Delegate microphone with transmission link to
auxiliary output
table 7.3: Combined devices from input to output
Typical frequency response:
125 Hz to 20 kHz
Front-to-random sensitivity index:
> 4.6 dB
Rated equivalent sound pressure level due to inherent noise:
< 25 dB(A)
Total harmonic distortion @ overload:
< 1%
Crosstalk attenuation:
> 80 dB
7.2

Environmental conditions

table 7.4: Environmental conditions
Working conditions:
Fixed, stationary, transportable
Temperature range:
-20 to +70 °C (transport)
+5 to +45 °C (operation)
For EPS and contribution devices with an LCD, the maximum temperature is +40 °C.
Relative humidity:
< 95%
7.3

Safety

According Low Voltage Directive 73/23/EEC amended
by Directive 93/68 EEC.
For European countries: according EN60065.
Marking: CE
For international countries: IEC 60065 according
CB-Scheme.
For North America:
USA: ANSI/UL 60065
Canada: CAN/CSA no. 60065
Marking c-CSA-us.
Bosch Security Systems | 2007-02 | 9922 141 70525
Interpreter microphone with transmission link to
interpreter headphones
Interpreter microphone with transmission link to
delegate headphones
Interpreter microphone with transmission link to
auxiliary output
en | 35