Bosch DCN Next Generation Installation & User's Instructions page 61

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | Central Devices
Video cameras (refer to the DCN Next Generation
Data Brochure for recommended video cameras).
Allegiant video switcher with keyboard (refer to the
DCN Next Generation Data Brochure for
recommended video switchers).
Video displays (refer to the DCN Next Generation
Data Brochure for recommended video displays).
Central control unit.
PC with at least one serial port.
LBB4188 Camera Control software module.
8.9.5.3
Installation
1 Set the protocol and baudrate for serial port 1 and
serial port 2 (refer to section 8.3.2 and table 8.21).
2 Connect the serial ports of the central control unit to
the PC and the Allegiant video switcher (refer to
figure 8.27 and figure 8.28).
table 8.21: DCN-CCU to PC and AutoDome
Device
Serial port
PC
Port 1
Allegiant video
Port 2
switcher
9 pole D-type
(male)
DCD
1
RxD
2
TxD
3
DTR
4
SG
5
DSR
6
RTS
7
CTS
8
RI
9
DCN-CCU
figure 8.27: DCN-CCU to PC
Bosch Security Systems | 2007-02 | 9922 141 70525
figure 8.28: DCN-CCU to Allegiant
Settings
3 Connect a video display to the video output of the
Protocol:
Allegiant video switcher.
Full
4 Install the licence for the LBB4188 Camera Control
Baudrate:
software module in the CCU or network controller
115.2k
Protocol:
(refer to the DCN Next Generation Software
Camera control
Installation Instructions).
5 Start the LBB4188 Camera Control software module
Baudrate:
(refer to the User Manual of the LBB4188 Camera
19.2k
Control software module).
6 Set the pre-positions of the video cameras with the
keyboard of the Allegiant video switcher.
9 pole D-type
7 Make sure that all pre-positions of all video cameras
(female)
are correct.
1
DCD
8 Attach the pre-positions of the video cameras to the
2
RxD
seat numbers with the LBB4188 Camera Control
3
TxD
software module.
4
DTR
5
SG
6
DSR
7
RTS
8
CTS
9
RI
PC
9 pole D-type
(male)
DCD
1
RxD
2
TxD
3
DTR
4
SG
5
DSR
6
RTS
7
CTS
8
RI
9
DCN-CCU
Note
Refer to section 8.5.8 for maximum cable
lengths.
en | 61
9 pole D-type
(male)
1
SG
2
RxD
3
TxD
4
CTS
5
RTS
6
n.c.
7
SG
8
n.c.
9
n.c.
Allegiant