Bosch DCN Next Generation Installation & User's Instructions page 128

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | Central Devices
13.5.8 Setup
Use the 4 Setup menu item to open the Setup
sub-menu. Use the menu items in this sub-menu to
configure the cobranet interface (refer to table 13.11).
Note
To open the Setup sub-menu, you must
push and hold the knob for more than 3
seconds.
table 13. 1 1: Setup sub-menu (* = default)
Menu item
4A AGC
4B Routing
4C Unit Name
4D Defaults
13.5.9 Defaults
Use the Defaults sub-menu to put back the default
values for all parameters in the configuration menu
(refer to table 13.12).
table 13. 1 2: Defaults sub-menu (* = default)
Menu item
4D
Bosch Security Systems | 2007-02 | 9922 141 70525
Parameter
Input:
Input 1
Input 2
Input 3
Input 4
Input/output:
Input 1
Input 2
Input 3
Input 4
Output 1
Output 2
Output 3
Output 4
---
---
Parameter
Reset to defaults
Value
AGC:
On, Off
On, Off
On, Off
On, Off
Channel:
--, 00 to 31
--, 00 to 31
--, 00 to 31
--, 00 to 31
--, PA, 00 to 31
--, PA, 00 to 31
--, PA, 00 to 31
--, PA, 00 to 31
Name:
CobraNet*
Custom name
---
Value
No*
Yes
en | 128
Description
Sets the automatic gain
control (AGC) of the
audio inputs on and off
(refer to section 13.5. 1 0).
The channel that is
attached to the audio
input or audio output of
the cobranet interface.
(PA = public address
system.)
The name of the cobranet
interface (max. 16
characters).
Opens the Reset menu
item (refer to section
13.5.9)
Description
Does not put back the
default values.
Sets all parameters to the
default values. The name
is not changed.

Advertisement

Table of Contents
loading

Table of Contents