Internal Settings - Bosch DCN Next Generation Installation & User's Instructions

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | Installation Devices
41.3

Internal settings

The rear of the cover of the network splitter shows a
label that gives data of the internal connections (refer to
figure 41.2). You can change the internal connections
with the jumper blocks inside the network splitter.
figure 41.2: Label inside network splitter
To supply additional power to the tap-offs that are
connected to the network splitter:
1 Put jumper shunt 1/2 on position 1.
2 Put jumper shunt 9/10 on position 10.
3 Connect an external power supply to the network
splitter (refer to section 42.4.2).
Bosch Security Systems | 2007-02 | 9922 141 70525
Tap-off powered
from:
9
Current limit
10
Tap-off 1
3 4 5
Current limit
Tap-off 2
External power
6 7 8
1
2
LED
11
12
Main network
1
External power
2
0.8 A
3
1.6 A
4
2.5 A
5
0.8 A
6
1.6 A
7
2.5 A
8
On
9
follows
10
Main network
Fault
11
Power
12
en | 231