DCN Next Generation | Installation and User Instructions | Flush-mounted Devices
24
DCN-FPRIOB Priority
Panel
Caution
Before you touch the priority panel, take
measures to prevent electro-static discharges.
24. 1

Introduction

With the DCN-FPRIOB Priority Panel, chairmen can
disable the microphones of all delegate devices. The
priority panel must be used with the DCN-DDI Dual
Delegate Interface in the chairman mode.
24.2 Controls, connectors and
indicators
The priority panel (refer to figure 24.1) contains:
1 Priority button - Disables the microphones of all
delegate devices and enables the microphone of the
chairman device when it is pushed. The priority
control button has a LED ring that shows the
condition of the microphone (refer to section 24.5).
Note
The system has the possibility to:
Play an attention chime when the chairman
pushes the priority button (refer to section
8.8.3).
Erase the request-to-speak list and the
speakers list when the chairman pushes the
priority button (refer to section 8.8.4).
figure 24. 1 : Priority panel
Bosch Security Systems | 2007-02 | 9922 141 70525
1

24.3 Installation

The priority panel is a flush-mounted device. Refer to
chapter 19 for the installation procedures.
table 24. 1 : Physical characteristics
Dimensions (h x w x d):
40 x 50 mm (built-in depth about 50 mm)
Weight:
54 g

24.4 External connections

A Cat-4 cable with RJ11 plugs is supplied with the
priority panel. Use this cable to connect the panel to the
DCN-DDI Dual Delegate Interface (refer to section 21.4
and section 21.6).
table 24.2: Power consumption
Power consumption:
0.25 W

24.5 Operation

The red LED ring comes on when you push the priority
button.