DCN Next Generation | Installation and User Instructions | Central Devices
13.5.10 Automatic gain control (AGC)
Use the AGC menu item to enable or disable the AGC
of the audio inputs. If necessary, enable the AGC for the
audio inputs that inject external interpretations in the
system. The AGC makes sure that the nominal level of
the received interpretations is 9 dBV (XLR), -6 dBV
(cinch). When the nominal input of an external
interpretation is high, the audio of the external
interpretations will be too loud compared to the audio
of the 'internal' interpretations from the interpreter
desks.
Note
When channel 00 is attached to an audio input,
the system automatically disables AGC for the
audio input. You cannot manually enable AGC
for an audio input to which channel 00 is
attached.
Note
If two systems are connected by audio
connections (Cobranet, AEX, or DEX), set the
AGC to off.
13.6

CobraNet Discovery

13.6.1 Introduction
With the CobraNet Discovery, you can:
Find the IP addresses of the devices that are
connected to the CobraNet network with a PC.
Change the IP addresses of the devices that are
connected to the CobraNet network with a PC.
Change the firmware of the devices that are
connected to the CobraNet network with a PC.
Note
We assume that you understand the basic
theory of CobraNet networks.
Bosch Security Systems | 2007-02 | 9922 141 70525
13.6.2 Installation
Install the CobraNet Discovery in a PC with the
CD-ROM that is supplied with your system. The
CD-ROM contains an automatic set-up program.
13.6.3 Start
Make sure that the PC in which you installed the
CobraNet Discovery is connected to the CobraNet
network. On the PC, go to Start > Programs >
CobraNet Discovery. The monitor of the PC shows the
CobraNet(tm) Discovery window (refer to figure 13.7 for
an example).
13.6.4 Operation
The CobraNet(tm) Discovery window (refer to figure
13.7) shows the CobraNet devices on the CobraNet
network and their Ethernet parameters.
Note
The list also shows PC in which CobraNet
Discovery is installed.
figure 13.7: CobraNet(tm) Discovery window
The list contains these data:
1 S(tatus) - Shows the condition of the CobraNet
device. If the status column contains a green
checkmark, the device is active. If the status column
contains a red cross, the device is not active or not
connected to the network.
2 MAC Address - Shows the MAC address of the
CobraNet device.
en | 129