Installing the Krone cross-connect system (UK)

NN43021-310
Standard 06.01
Planning and designating a Main Distribution Frame
In the Krone cross-connect system, one terminating strip holds ten pairs of
cable. When cross-connecting a 25-pair cable on this system, eight of the
ten terminating points are used on each strip. One 25-pair cable, therefore,
occupies three terminating strips:
8 pairs per strip by 3 strips = 24 pairs
Card allocations
Figures 52 and 53 provide module card allocations for the Krone
cross-connect system.
Procedure 12 describes how to install the Krone Test Jack Frame for the UK.
Procedure 12
Installing the Krone Test Jack Frame (UK)
1
Refer to the equipment layout plan to determine where to place the
cross-connect terminal.
2
Lay out the terminal blocks.
3
Attach labels on the cross-connect terminal to indicate the terminal blocks
assigned to the following:
Analog line cards
DC15/AC15/RAN/PAG cards
Data Access cards
AUX wiring
Power Failure Transfer Units
Digital line cards
Telephones
Exchange line trunk cards
Direct Dialing Inward trunk cards
Miscellaneous equipment
March 2013
End of Procedure