Page 138 of 436
Terminal block requirements
Installing the BIX cross-connect terminal
NN43021-310
Standard 06.01
Planning and designating a Main Distribution Frame
This chapter describes how to install and connect an Avaya Communication
Server 1000M system using the BIX or Krone Test Jack Frame (UK)
cross-connect terminals.
Note: The examples shown here are BIX and Krone cross-connect
systems. These items are commercially available, but are not supplied by
Avaya.
This chapter contains the following procedures:
•
Procedure 11: "Installing the BIX cross-connect terminal" on
•
Procedure 12: "Installing the Krone Test Jack Frame (UK)" on
The cross-connect terminal requires enough connecting blocks to terminate:
•
up to 16 25-pair cables for each IPE shelf
•
up to four 25-pair cables for each Media Gateway and Media Gateway
Expander
•
four conductors for the AUX cable from the Media Gateway
•
one 25-pair cable from each PFTU
•
wiring from telephones and trunks.
DANGER
Always use caution when installing or modifying
telephone lines. Do not install telephone wiring during a
lightning storm. Never touch uninsulated telephone
wiring, unless the line is disconnected at the network
interface.
Procedure 11 describes how to install the BIX cross-connect terminal.
March 2013
page
139.
page
142.