Adding a module to a column
5
Connect the power and system monitor cables in the module:
a.
Connect the power connectors to the pedestal and to the module
above (see Figure 115 on
b.
Attach the frame ground wires to the frame ground post at the base
of the module.
c.
Connect the system monitor cable from the pedestal to connector J1
on the module being added.
d.
Connect the system monitor cable from connector J2 in the module
being added to J1 in the module above.
6
Set all circuit breakers in the pedestal to ON.
7
Reinstall the system monitor in the pedestal:
a.
Reconnect the RJ11 cable to J6, then the cable to J3. Reinstall the
system monitor.
b.
If the column houses the master system monitor, load LD 37, and
software re-enable the associated SDI port:
LD 37
ENL TTY x
****
8
Replace all module covers and the pedestal grill.
March 2013
page 350
and Figure 117 on
enable the device associated with the port
exit LD 37
End of Procedure