Installing Earthquake Rods - Avaya 1000M Installation And Commissioning Manual

Communication server
Hide thumbs Also See for 1000M:
Table of Contents

Advertisement

Installing earthquake rods

Procedure 59
Installing Kit B
1
Locate the two mounting plates for each column over the anchor holes.
Insert the anchors into the holes and tap the anchors into place with a
mallet.
2
Level the plates with shims. Leave the stack of shims exposed until all
leveling has been completed (this will allow the addition or removal of
shims if necessary).
3
If the installation must meet CALIFORNIA OSHPD, tension proof load
testing is required on 50% of the anchor bolts. These anchors must be
tested to 6230 N (1400 lb) tension and 122 J (90 ft-lb) torque. Any failure
requires testing of all remaining anchors.
4
Go to "Installing earthquake rods" on
The following tools are required to install the rods:
7.5 mm (5/16 in.) socket wrench
12.7 mm (1/2 in.) open-end wrench for rods
14.3 mm (9/16 in.) open-end wrench for nuts
Note: The earthquake rods should be installed before you position the
columns.
Installing earthquake bracing
page
End of Procedure
Large System Installation and Commissioning
Page 335 of 436
335.

Advertisement

Table of Contents
loading

Table of Contents