Danfoss vlt fc 300 Instruction Manual page 85

Automation drive 12-pulse
Hide thumbs Also See for vlt fc 300:
Table of Contents

Advertisement

VLT
How to Program
Instruction Manual High Power
Par.
Parameter description
No.
#
30-22 Locked Rotor Protection
30-23 Locked Rotor Detection Time [s]
30-8* Compatibility (I)
30-80 d-axis inductance (Ld)
4
4
30-81 Brake Resistor (ohm)
30-83 Speed PID Proportional Gain
30-84 Process PID Proportional Gain
Table 4.23
4.3.21 32-** MCO Basic Settings
Par.
Parameter description
No.
#
32-0* Encoder 2
32-00 Incremental Signal Type
32-01 Incremental Resolution
32-02 Absolute Protocol
32-03 Absolute Resolution
32-04 Absolute Encoder Baudrate X55
32-05 Absolute Encoder Data Length
32-06 Absolute Encoder Clock Frequency
32-07 Absolute Encoder Clock Generation
32-08 Absolute Encoder Cable Length
32-09 Encoder Monitoring
32-10 Rotational Direction
32-11 User Unit Denominator
32-12 User Unit Numerator
32-13 Enc.2 Control
32-14 Enc.2 node ID
32-15 Enc.2 CAN guard
32-3* Encoder 1
32-30 Incremental Signal Type
32-31 Incremental Resolution
32-32 Absolute Protocol
32-33 Absolute Resolution
32-35 Absolute Encoder Data Length
32-36 Absolute Encoder Clock Frequency
32-37 Absolute Encoder Clock Generation
32-38 Absolute Encoder Cable Length
32-39 Encoder Monitoring
32-40 Encoder Termination
32-43 Enc.1 Control
32-44 Enc.1 node ID
32-45 Enc.1 CAN guard
32-5* Feedback Source
32-50 Source Slave
4-28
MG34Q222 - VLT
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
®
Automation Drive FC 300 12-Pulse
Default value
4 set-up
FC 302
Change
only
during
operation
[0] Off
All set-ups
x
TRUE
0.10 s
All set-ups
x
TRUE
ExpressionLimit
All set-ups
x
FALSE
ExpressionLimit
1 set-up
TRUE
ExpressionLimit
All set-ups
TRUE
0.100 N/A
All set-ups
TRUE
Default value
4 set-up
FC 302
Change
only
during
operation
[1] TTL (5V, RS4222)
2 set-ups
TRUE
1024 N/A
2 set-ups
TRUE
[0] None
2 set-ups
TRUE
8192 N/A
2 set-ups
TRUE
[4] 9600
All set-ups
FALSE
25 N/A
2 set-ups
TRUE
262.000 kHz
2 set-ups
TRUE
[1] On
2 set-ups
TRUE
0 m
2 set-ups
TRUE
[0] Off
2 set-ups
TRUE
[1] No action
2 set-ups
TRUE
1 N/A
2 set-ups
TRUE
1 N/A
2 set-ups
TRUE
[0] No soft changing
2 set-ups
TRUE
127 N/A
2 set-ups
TRUE
null
2 set-ups
TRUE
[1] TTL (5V, RS4222)
2 set-ups
TRUE
1024 N/A
2 set-ups
TRUE
[0] None
2 set-ups
TRUE
8192 N/A
2 set-ups
TRUE
25 N/A
2 set-ups
TRUE
262.000 kHz
2 set-ups
TRUE
[1] On
2 set-ups
TRUE
0 m
2 set-ups
TRUE
[0] Off
2 set-ups
TRUE
[1] On
2 set-ups
TRUE
[0] No soft changing
2 set-ups
TRUE
127 N/A
2 set-ups
TRUE
null
2 set-ups
TRUE
[2] Encoder 2
2 set-ups
TRUE
®
is a registered Danfoss trademark
Conver-
Type
sion
index
-
Uint8
-2
Uint8
-6
Int32
-2
Uint32
-4
Uint32
-3
Uint16
Conver-
Type
sion
index
-
Uint8
0
Uint32
-
Uint8
0
Uint32
-
Uint8
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint32
0
Uint32
-
Uint8
0
Uint8
-
Uint8
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint8
0
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8