VLT
How to Program
Instruction Manual High Power
Par.
Parameter description
No.
#
1-65
Resonance Dampening Time Constant
1-66
Min. Current at Low Speed
1-67
Load Type
1-68
Minimum Inertia
4
4
1-69
Maximum Inertia
1-7* Start Adjustments
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-74
Start Speed [RPM]
1-75
Start Speed [Hz]
1-76
Start Current
1-8* Stop Adjustments
1-80
Function at Stop
1-81
Min Speed for Function at Stop [RPM]
1-82
Min Speed for Function at Stop [Hz]
1-83
Precise Stop Function
1-84
Precise Stop Counter Value
1-85
Precise Stop Speed Compensation Delay
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Resource
1-94
ATEX ETR cur.lim. speed reduction
1-95
KTY Sensor Type
1-96
KTY Thermistor Resource
1-97
KTY Threshold level
1-98
ATEX ETR interpol. points freq.
1-99
ATEX ETR interpol points current
Table 4.6
4.3.4 2-** Brakes
Par.
Parameter description
No.
#
2-0* DC Brake
2-00
DC Hold Current
2-01
DC Brake Current
2-02
DC Braking Time
2-03
DC Brake Cut-in Speed [RPM]
2-04
DC Brake Cut-in Speed [Hz]
2-05
Maximum Reference
2-1* Brake Energy Funct.
2-10
Brake Function
2-11
Brake Resistor (ohm)
2-12
Brake Power Limit (kW)
4-10
MG34Q222 - VLT
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
®
Automation Drive FC 300 12-Pulse
Default value
4 set-up
FC 302
Change
only
during
operation
5 ms
All set-ups
TRUE
100 %
All set-ups
x
TRUE
[0] Passive load
All set-ups
x
TRUE
ExpressionLimit
All set-ups
x
FALSE
ExpressionLimit
All set-ups
x
FALSE
0.0 s
All set-ups
TRUE
[2] Coast/delay time
All set-ups
TRUE
null
All set-ups
FALSE
ExpressionLimit
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
0.00 A
All set-ups
TRUE
[0] Coast
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
[0] Precise ramp stop
All set-ups
FALSE
100000 N/A
All set-ups
TRUE
10 ms
All set-ups
TRUE
[0] No protection
All set-ups
TRUE
[0] No
All set-ups
TRUE
[0] None
All set-ups
TRUE
0.0 %
2 set-ups
x
TRUE
[0] KTY Sensor 1
All set-ups
x
TRUE
[0] None
All set-ups
x
TRUE
80 °C
1 set-up
x
TRUE
ExpressionLimit
1 set-up
x
TRUE
ExpressionLimit
2 set-ups
x
TRUE
Default value
4 set-up
FC 302
Change
only
during
operation
50 %
All set-ups
TRUE
50 %
All set-ups
TRUE
10.0 s
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
MaxReference (P303)
All set-ups
TRUE
null
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
®
is a registered Danfoss trademark
Conver-
Type
sion
index
-3
Uint8
0
Uint32
-
Uint8
-4
Uint32
-4
Uint32
-1
Uint8
-
Uint8
-
Uint8
67
Uint16
-1
Uint16
-2
Uint32
-
Uint8
67
Uint16
-1
Uint16
-
Uint8
0
Uint32
-3
Uint8
-
Uint8
-
Uint16
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
100
Int16
-1
Uint16
0
Uint16
Conver-
Type
sion
index
0
Uint8
0
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-3
Int32
-
Uint8
0
Uint16
0
Uint32