General Specifications
Instruction Manual High Power
Line Power Supply 6x525–690 V AC, 12-Pulse
FC 302
P900
High/ Normal Load*
HO
Typical Shaft output at 550 V
[kW]
750
Typical Shaft output at 575 V
[HP]
1,050
Typical Shaft output at 690 V
1,207 hp
1,340 hp
[hp, kW]
[900 kW]
[1,000 kW]
Enclosure IP21, IP54 without/
F12/F13
with options cabinet
Output current
5
5
Continuous
988
(at 550 V) [A]
Intermittent (60 s overload)
1,482
(at 550 V) [A]
Continuous
945
(at 575/690 V) [A]
Intermittent (60 s overload)
1,418
(at 575/690 V) [A]
Continuous KVA
941
(at 550 V) [KVA]
Continuous KVA
941
(at 575 V) [KVA]
Continuous KVA
1,129
(at 690 V) [KVA]
Max. input current
Continuous
962
(at 550 V) [A]
Continuous
920
(at 575 V) [A]
Continuous
920
(at 690 V) [A]
Max. cable size, motor [mm
2
(AWG
2)
)]
Max. cable size, line power F12
2
2)
[mm
(AWG
)]
Max. cable size, line power F13
[mm
2
(AWG
2)
)]
Max. cable size, brake [mm
2
2)
(AWG
)
Max. external electrical fuses
1,600
[A] 1
Estimated power loss
18,445 hp,
20.909 hp,
4)
[13,755 W]
[15,592 W]
at 600 V [hp, W]
Estimated power loss
19.387 hp,
21.959 hp,
at 690 V [W]
4)
[14,457 W]
[16,375 W]
F3/F4 Max added losses CB or
556
Disconnect & Contactor
Max panel options losses
Weight,
2747/3397 [1246/1541]
enclosure IP21, IP54 (lb [kg])
Weight, Rectifier Module (lb
[kg])
Weight, Inverter Module (lb
[kg])
4)
Efficiency
Output frequency
Heatsink overtemp. trip
Power card ambient trip
* High overload = 160% torque during 60 s, Normal overload = 110% torque during 60 s
Table 5.5
5-10
MG34Q222 - VLT
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
®
Automation Drive FC 300 12-Pulse
P1M0
P1M2
NO
HO
NO
HO
NO
HO
850
850
1,000
1,000
1,100
1,100
1,150
1,150
1,350
1,350
1,550
1,550
1,340 hp
1,610 hp
1,610 hp
1,875 hp
1,875 hp
[1,000 kW]
[1,200 kW]
[1,200 kW]
[1,400 kW]
[1,400 kW]
F12/F13
F12/F13
1,108
1,108
1,317
1,317
1,479
1,479
1,219
1,662
1,449
1,976
1,627
2,218.5
1,060
1,060
1,260
1,260
1,415
1,415
1,166
1,590
1,386
1,890
1,557
2,122
1,056
1,056
1,255
1,255
1,409
1,409
1,056
1,056
1,255
1,255
1,409
1,409
1,267
1,267
1,506
1,506
1,691
1,348
1,079
1,079
1,282
1,282
1,440
1,440
1,032
1,032
1,227
1,227
1,378
1,378
1,032
1,032
1,227
1,227
1,378
1,378
12x150
(12x300 mcm)
8x240
(8x500 mcm)
8x400
(8x900 mcm)
6x185
(6x350 mcm)
2,000
2,500
20.259 hp,
24.515 hp,
24.381 hp,
27.927 hp,
25.269 hp,
[15,107 W]
[18,281 W]
[18,181 W]
[20,825 W]
[18,843 W]
21.321 hp,
25.757 hp,
25.620 hp,
29.311 hp,
25.736 hp,
[15,899 W]
[19,207 W]
[19,105 W]
[21,857 W]
[19,191 W]
665
634
863
861
1,044
1,016
536 hp [400 kW]
2747/3397 [1246/1541]
2822/3472 [1280/1575]
6784/7434 [3077/3372]
299.8 [136]
224.9 [102]
299.8 [136]
0.98
0–500 Hz
185° F [85° C]
167° F [75° C]
®
is a registered Danfoss trademark
P1M4
NO
1,250
1,700
2,145 hp
[1,600 kW]
F14
1,652
1,817.2
1,580
1,738
1,574
1,574
1,505
1,608
1,538
1,538
28.784 hp,
[21,464 W]
29.276 hp,
[21,831 W]