VLT
How to Program
Instruction Manual High Power
Par.
Parameter description
No.
#
10-14 Net Reference
10-15 Net Control
10-2* COS Filters
10-20 COS Filter 1
4
4
10-21 COS Filter 2
10-22 COS Filter 3
10-23 COS Filter 4
10-3* Parameter Access
10-30 Array Index
10-31 Store Data Values
10-32 Devicenet Revision
10-33 Store Always
10-34 DeviceNet Product Code
10-39 Devicenet F Parameters
10-5* CANopen
10-50 Process Data Config Write.
10-51 Process Data Config Read.
Table 4.15
4.3.13 12-** Ethernet
Par.
Parameter description
Default value
No.
#
12-0* IP Settings
12-00 IP Address Assignment
12-01 IP Address
12-02 Subnet Mask
12-03 Default Gateway
12-04 DHCP Server
12-05 Lease Expires
ExpressionLimit
12-06 Name Servers
12-07 Domain Name
12-08 Host Name
12-09 Physical Address
12-1* Eth link par
12-10 Link Status
[0] No Link
12-11 Link Duration
ExpressionLimit
12-12 Auto Negotiation
12-13 Link Speed
12-14 Link Duplex
[1] Full Duplex
12-2* Process Data
12-20 Control Instance
ExpressionLimit
12-21 Process Data Config Write
ExpressionLimit
12-22 Process Data Config Read
ExpressionLimit
12-23 Process Data Config Write Size
12-24 Process Data Config Read Size
4-20
MG34Q222 - VLT
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
®
Automation Drive FC 300 12-Pulse
Default value
4 set-up
FC 302
Change
only
during
operation
[0] Off
2 set-ups
TRUE
[0] Off
2 set-ups
TRUE
0 N/A
All set-ups
FALSE
0 N/A
All set-ups
FALSE
0 N/A
All set-ups
FALSE
0 N/A
All set-ups
FALSE
0 N/A
2 set-ups
TRUE
[0] Off
All set-ups
TRUE
ExpressionLimit
All set-ups
TRUE
[0] Off
1 set-up
TRUE
ExpressionLimit
1 set-up
TRUE
0 N/A
All set-ups
TRUE
ExpressionLimit
2 set-ups
TRUE
ExpressionLimit
2 set-ups
TRUE
4 set-up
FC 302
Change
Conver-
only
during
sion index
operation
null
2 set-ups
TRUE
0 N/A
1 set-up
TRUE
0 N/A
1 set-up
TRUE
0 N/A
1 set-up
TRUE
0 N/A
2 set-ups
TRUE
All set-ups
TRUE
0 N/A
1 set-up
TRUE
0 N/A
1 set-up
TRUE
0 N/A
1 set-up
TRUE
0 N/A
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
[1] On
2 set-ups
TRUE
[0] None
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
16 N/A
All set-ups
TRUE
16 N/A
All set-ups
TRUE
®
is a registered Danfoss trademark
Conver-
Type
sion
index
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint8
-
Uint8
0
Uint16
-
Uint8
0
Uint16
0
Uint32
-
Uint16
-
Uint16
Type
-
Uint8
0
OctStr[4]
0
OctStr[4]
0
OctStr[4]
0
OctStr[4]
0
TimD
0
OctStr[4]
0
VisStr[48]
0
VisStr[48]
0
VisStr[17]
-
Uint8
0
TimD
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint16
-
Uint16
0
Uint32
0
Uint32