VLT
How to Program
Instruction Manual High Power
Par.
Parameter description
No.
#
13-10 Comparator Operand
13-11 Comparator Operator
13-12 Comparator Value
13-1* RS Flip Flops
4
4
13-15 RS-FF Operand S
13-16 RS-FF Operand R
13-2* Timers
13-20 SL Controller Timer
13-4* Logic Rules
13-40 Logic Rule Boolean 1
13-41 Logic Rule Operator 1
13-42 Logic Rule Boolean 2
13-43 Logic Rule Operator 2
13-44 Logic Rule Boolean 3
13-5* States
13-51 SL Controller Event
13-52 SL Controller Action
Table 4.17
4.3.15 14-** Special Functions
Par.
Parameter description
No.
#
14-0* Inverter Switching
14-00 Switching Pattern
14-01 Switching Frequency
14-03 Overmodulation
14-04 PWM Random
14-1* Line Power On/Off
14-10 Line Failure
14-11 AC Line Voltage at Line Fault
14-12 Function at Line Imbalance
14-2* Trip Reset
14-20 Reset Mode
14-21 Automatic Restart Time
14-22 Operation Mode
14-23 Typecode Setting
14-24 Trip Delay at Current Limit
14-25 Trip Delay at Torque Limit
14-26 Trip Delay at Inverter Fault
14-28 Production Settings
14-29 Service Code
14-3* Current Limit Ctrl.
14-30 Current Lim Cont, Proportional Gain
14-31 Current Lim. Contr., Integration Time
14-4* Energy Optimizing
4-22
MG34Q222 - VLT
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
®
Automation Drive FC 300 12-Pulse
Default value
4 set-up
FC 302
Change
only
during
operation
null
2 set-ups
TRUE
null
2 set-ups
TRUE
ExpressionLimit
2 set-ups
TRUE
null
2 set-ups
TRUE
null
2 set-ups
TRUE
ExpressionLimit
1 set-up
TRUE
null
2 set-ups
TRUE
null
2 set-ups
TRUE
null
2 set-ups
TRUE
null
2 set-ups
TRUE
null
2 set-ups
TRUE
null
2 set-ups
TRUE
null
2 set-ups
TRUE
Default value
4 set-up
FC 302
Change
only
during
operation
[1] SFAVM
All set-ups
TRUE
null
All set-ups
TRUE
[1] On
All set-ups
FALSE
[0] Off
All set-ups
TRUE
[0] No function
All set-ups
FALSE
SR
All set-ups
TRUE
[0] Trip
All set-ups
TRUE
[0] Manual reset
All set-ups
TRUE
10 s
All set-ups
TRUE
[0] Normal operation
All set-ups
TRUE
null
2 set-ups
FALSE
60 s
All set-ups
TRUE
60 s
All set-ups
TRUE
SR
All set-ups
TRUE
[0] No action
All set-ups
TRUE
0 N/A
All set-ups
TRUE
100 %
All set-ups
FALSE
0.020 s
All set-ups
FALSE
®
is a registered Danfoss trademark
Conver-
Type
sion
index
-
Uint8
-
Uint8
-3
Int32
-
Uint8
-
Uint8
-3
TimD
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Conver-
Type
sion
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Int32
0
Uint16
-3
Uint16