VLT
Automation Drive FC 300 12-Pulse
How to Program
Instruction Manual High Power
Par.
Parameter description
Default value
No.
#
7-13
Torque PI Integration Time
0.020 s
7-2* Process Ctrl. Feedb
7-20
Process CL Feedback 1 Resource
[0] No function
7-22
Process CL Feedback 2 Resource
[0] No function
7-3* Process PID Ctrl.
7-30
Process PID Normal/Inverse Control
[0] Normal
7-31
Process PID Anti Windup
[1] On
7-32
Process PID Controller Start Value
0 RPM
7-33
Process PID Proportional Gain
0.01 N/A
7-34
Process PID Integral Time
10000.00 s
7-35
Process PID Differentiation Time
0.00 s
7-36
Process PID Differentiation Gain Limit
5.0 N/A
7-38
Process PID Feed Forward Factor
0 %
7-39
On Reference Bandwidth
5 %
7-4* Adv. Process PID I
7-40
Process PID I-part Reset
[0] No
7-41
Process PID Output Neg. Clamp
-100 %
7-42
Process PID Output Pos. Clamp
100 %
7-43
Process PID Gain Scale at Min. Ref.
100 %
7-44
Process PID Gain Scale at Max. Ref.
100 %
7-45
Process PID Feed Fwd Resource
[0] No function
7-46
Process PID Feed Fwd Normal/ Inv. Ctrl.
[0] Normal
7-48
PCD Feed Forward
0 N/A
7-49
Process PID Output Normal/ Inv. Ctrl.
[0] Normal
7-5* Adv. Process PID II
7-50
Process PID Extended PID
[1] Enabled
7-51
Process PID Feed Fwd Gain
1.00 N/A
7-52
Process PID Feed Fwd Ramp-up
0.01 s
7-53
Process PID Feed Fwd Ramp-down
0.01 s
7-56
Process PID Ref. Filter Time
0.001 s
7-57
Process PID Fb. Filter Time
0.001 s
Table 4.12
4.3.10 8-** Comm. and Options
Par.
Parameter description
Default value
No.
#
8-0* General Settings
8-01
Control Site
[0] Digital and ctrl. word
8-02
Control Word Source
null
8-03
Control Word Timeout Time
1.0 s
8-04
Control Word Timeout Function
null
8-05
End-of-Timeout Function
[1] Resume set-up
8-06
Reset Control Word Timeout
[0] Do not reset
8-07
Diagnosis Trigger
[0] Disable
8-08
Readout Filtering
null
8-1* Ctrl. Word Settings
MG34Q222 - VLT
®
is a registered Danfoss trademark
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
4 set-up
FC 302
Change
Conver-
Type
only
during
sion
operation
index
All set-ups
TRUE
-3
Uint16
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
4
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
67
Uint16
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint32
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-1
Uint16
All set-ups
TRUE
0
Uint16
All set-ups
TRUE
0
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
0
Int16
All set-ups
TRUE
0
Int16
All set-ups
TRUE
0
Int16
All set-ups
TRUE
0
Int16
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
x
TRUE
0
Uint16
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint32
All set-ups
TRUE
-2
Uint32
All set-ups
TRUE
-3
Uint16
All set-ups
TRUE
-3
Uint16
4 set-up
FC 302
Change
Conver-
Type
only
during
sion
operation
index
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
1 set-up
TRUE
-1
Uint32
1 set-up
TRUE
-
Uint8
1 set-up
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
2 set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
4-17
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the vlt fc 300 and is the answer not in the manual?

Table of Contents