Programming Overview; Entering Programming Mode; Exiting Programming Mode; Navigating The Menu - Bosch Solution 16plus Quick Start Manual

Hide thumbs Also See for Solution 16plus:
Table of Contents

Advertisement

Solution 16
Quick Start Guide
plus
Pro gra mm i n g O ver vi ew
The Solution 16
plus
Control System incorporates a menu
text driven interface. This interface is very similar to that
found on many mobile phones. Once programming mode
is entered you will see a number of menu options in the
display and these may vary depending in the user authority
level.
Ente r i ng Program mi n g M o de
To enter installer program mode enter, PIN + [MENU].
The default Installer PIN is 1234.
The Red and Green LED indicators on the keypad will flash
to confirm Installer programming mode is active.
All areas must be disarmed with no active alarms.
i
To disarm all areas enter the Installer PIN and hold
Note
the [OFF] Key for 2 seconds.
E x i ti ng Program m i ng M ode
Press and hold down [MENU] key for 2 seconds.
You can also select Exit and press [OK] from each
i
menu level.
Note
Nav ig ating Th e M enu
Using the up and down arrow keys to navigate, locate the
desired menu item using the highlight bar and then press
the [OK] key to select.
A new list of menu items will appear. Repeat the above
until the desired menu item is located.
To navigate backwards through the menu items press the
[MENU] key at any time. Alternatively if you know the direct
menu item number press [MENU] + Item Number.
Key
Scrolls Cursor Left
Scrolls Cursor Right
Scrolls Cursor Up
Scrolls Cursor Down
OK
Enter Menu Options or Saves Changes
Go Back One Level, Hold Down to Exit
MENU
Programming Mode
0 to 9
Enter Data Value
ON
Turn On Bit Option
OFF
Turn Off Bit Option, Clear to End of Line

Table 7: Keys Used During Programming

Co m ma nd M en u
When you first enter programming mode a special menu
called the Command Menu will appear at the top of the
menu tree. The Command Menu provides a list of the
most common system funtions like "Turn Chime Mode On",
12
Description
"Move To An Area" or "Turn An Area On". Use the up and
down arrow keys to navigate and press [OK] to select the
command.
Pro gra m ming O ption B it M e nus
Use the up and down arrow keys to scroll through the 8
different options. To select an option, press the [ON] key
– a tick [] will be displayed. To deselect an option, press
the [OFF] key.
Off On Low Battery
Show Overload
 Report Overload
Press


Figure 15: Sample Option Bit Menu Display

To save programming changes, press [OK], else press
[MENU] to exit without saving.
Alp ha Tex t
Text descriptions are available for Area Name, Zone Name,
User Name, Schedule Name, Holiday Name Prox Reader
Name and Output Name. Each name can have a maximum
of 16 characters.
Area 2 Name
Reception Area
PRESS ◄►


Figure 16: Area Text Programming Display

When programming text, each numeric key represents a
different group of characters.
Pressing the same numeric key repeatedly will step you
through the available characters assigned to the key. The
text key layout is the same as most phones. Refer to the
table below for detailed character information.
Key
Characters Assigned To Each Numeric Key
1
.
,
?
2
A
B
C
3
D
E
F
4
G
H
5
J
K
L
6
M
N
O
7
P
Q
R
8
T
U
V
9
W
X
Y
0
SPACE
0
Scroll Up through entire character list
Scroll Down through entire character list
Move to left one character position
Move to right one character position
OFF
Clear from cursor postiion to end of line

Table 8: Text Keypad Character Set

Once the desired character is displayed press the right
arrow key to move to the next character position.
To save programming changes, press [OK], else press
OK ON OFF MENU
, OK or MENU
!
-
&
`
a
b
c
2
d
e
f
3
I
g
h
i
4
j
k
l
5
m
n
o
6
S
p
q
r
t
u
v
8
Z
w
x
y
Bosch Security Systems 09/06 BLCC100R
1
s
7
z
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents