Config Show - Avaya IPBS1 Installation And Operation Manual

Ip-dect base station and ip-dect gateway
Table of Contents

Advertisement

CPU-R
MEM
ETH0
Concurrent calls
Temperature (only for IPBL)
Voltage (only for IPBL)
1. Select Diagnostics > Performance
2. Select the checkbox(es) for the desired performance statistics.
3. Click "OK".
4. One window shows statistics for the last 24 hours. The maximum possible value is
displayed in the top-left corner. Click the left or right arrow buttons to see different time
frames.

Config Show

Under Diagnostics > Config Show, the configuration is displayed as a text output.
Avaya 374x DECT Telephones - User Guide
Shows utilization of CPU resources allocated by
different tasks. If the CPU resources are fully utilized it
will prevent connection of more calls. One solution in
that case can be to install an additional Base Station in
the same coverage area.
Shows utilization of the RAM memory. If the
utilization is continuously and significantly increasing
then it can be due to memory leakage. It can also be due
to a large number of simultaneous ongoing events.
Another reason can be that a Base Station has to much
to handle and a solution can be to divide the roles of
Pari Master, Radio etc. on several Base Stations. The
displayed utilization curve will never decrease as it
shows the amount of memory that has been dedicated to
a specific memory pool. Within each memory pool it
can still be reused.
Shows the traffic on the Base Station's ethernet
interface.
Shows the number of simultaneous ongoing calls on the
Base Station's air interface. Maximum number of calls
that can be handled simultaneous in air is 8. If the
number of concurrent calls is 8 for a longer time, a
solution could be to add an additional Base Station to
the system.
Shows the temperature of the cabinet.
Shows the power supply voltage level.
An alarm warning about high voltage will be sent at 54
V.
An alarm warning about low voltage will be sent at 42
V.
The IPBL will shut down when the voltage drops below
36 V or goes above 60 V.