Cordless Extension Number Test - Avaya IPBS1 Installation And Operation Manual

Ip-dect base station and ip-dect gateway
Table of Contents

Advertisement

2. Mark areas where cracking sounds or mutes are heard.
Evaluation
After having performed the coverage area test, the results should be evaluated. If the coverage
is not sufficient you should review the planning and move or add equipment.

Cordless Extension Number Test

This test checks for each handset the complete connection from the IP-DECT system to the
PBX. Furthermore it checks that the handsets' numbers have been correctly programmed. The
test is performed by calling all handset from one specific handset.
1. Put all handset together in order of extension number on a table.
2. Go off-hook with each handset and check that the dial tone is heard.
3. Call with a handset (handset A) all other handsets sequentially and check that the
handset with the corresponding number on its display rings when called.
4. Call handset A and check if it rings.
144