LED indication
Status LED
Not lit
Flashing slow green
Flashing fast green
Steady green
Steady red
Steady amber
Base station LED
Not lit
Flashing
Steady
Base station LED
Not lit
Flashing
Steady
Sync/Ref sync LED
Not lit
Steady
Sync/Ref sync LED
Not lit
Flashing
Steady
18
Avaya 374x DECT Telephones - User Guide
Figure 1.
Figure 2.
Figure 3.
Description
Not powered, status is not defined.
When pressing the reset button.
Firmware update or clear config after long reset.
Status OK, system is fully operational.
Status Fail, system error condition.
System is in TFTP server mode.
Description
No U
link established.
PN
U
link established (activated state), RFP is
PN
not operational.
RFP is fully initialised and operational.
Description
No speech activity in RFP.
All speech channels occupied in RFP.
Speech activity in RFP.
Description
No sync communication established.
Communication established.
Description
Sync port not selected as input sync source.
Sync port selected as input sync source but the
sync signal is not in sync.
Sync port selected as input sync source and the
sync signal is in sync.
02/2016