Sync OUT

RFP Cable

The RFP cable connects the IPBL with the RFPs. The maximum cable length between IPBL
and a single RFP must not exceed 1500 meters.
Note: Ensure that during the installation, each RFP is given an extra length (5-10 metres) of cable
because it is possible that it will have to be moved for one reason or another.
1. Cut the cable to the correct length.
2. Connect the cable to a RJ45 modular jack. For information on the pinning, see below.
IMPORTANT: If local power supply is used for the RFP, the EPP cable pairs must NOT be connected.
3. Label the cable.
Avaya 374x DECT Telephones - User Guide
Figure 13.
RJ45
modular jack
Figure 18. Connector pinning of the Sync OUT cable
RJ45
modular jack
1
2
1
2
3
4
5
6
7
8
EPP= Express Power pairs
SC = Data pair lead
NC= Not Connected
3
4
5
6
7
8
EPP= Express Power pairs
SC = Data pair lead
NC= Not Connected
Installation of the IPBL
49