Configure Sync Master Ipbs - Avaya IPBS1 Installation And Operation Manual

Ip-dect base station and ip-dect gateway
Table of Contents

Advertisement

Configure Sync Slave as follows:
1. Select DECT > Air Sync.
2. Select "Slave" in the Sync Mode drop-down list.
3. To lock the sync slave to a specific RFPI, enter the sync RFPI in the Sync RFPI text field.
Enter an alternative sync RFPI in the Alternative Sync RFPI text field (optional).
4. Enter a region ID between 0 and 63 in the Sync Region text field.
5. Click "OK".

Configure Sync Master IPBS

Radios configured as sync master will report to the Master that it wants to be a sync master.
The Master will select one of them to be the active sync master.
When a sync master has been assigned to be active it searches for other IPBSs within the
same region during 30 seconds. If any IPBS is found the values for slot, frame, multi frame and
PSCN are received and applied to the Sync Master. After receiving all these values or after the
time-out of 30 seconds the Sync Master enters the master state.
With this method it will be possible to restart only the Master in the region. The remaining slaves
will be able to maintain synchronization for a few minutes during restart of the Master. The
Master will adjust itself to the other IPBSs at startup. The slaves will notice that the Master is
back and the synchronization will be received from the Master.
In master state the values are updated locally during all further operation of the Master IPBS
and no synchronization to other IPBSs in the same region is done.
It is possible to configure the Sync Master to synchronize to a reference base station (another
or same DECT system). In this case the Sync Master will try to synchronize to the reference
system if the reference system is found but it will not require the reference system to be
available. The Sync Master will operate even though the reference system is not available.
During startup the Master will prefer to synchronize to a slave base in the same system before
synchronizing to the reference base station.
Configure Sync Master as follows:
1. Select DECT > Air Sync.
2. Select "Master" in the Sync Mode drop-down list.
3. To synchronize the sync master to a reference base station, enter the reference base
station in the Reference RFPI text field. Enter an alternative reference base station in the
Alternative reference RFPI text field (optional).
4. Enter a region ID between 0 and 63 in the Sync Region text field.
5. Select type of resynchronization action to perform at reference sync failure, a manual or an
automatic (scheduled) one.
6. Select Action at reference sync failure as one of the following:
Resynchronize on command (manually)
l
110
Avaya 374x DECT Telephones - User Guide
02/2016

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipbs2Ipbl

Table of Contents