Paradyne 9126 User Manual page 328

Paradyne router user's guide
Table of Contents

Advertisement

10. Setting Up NetScout Manager Plus for FrameSaver Devices
Procedure
Refer to Creating .UDH Files and Using Custom History in the NetScout Manager
Plus User Guide for additional information.
See
information for an interface.
10-14
1. Open a terminal window and go to $NSHOME/usr.
2. Copy an example or interface-specific file to a new file that contains the user
history table number.
3. Open the new file using a text editor.
The variables in the file are listed with their OIDs (Object IDs). The frame relay
interface number 101015001 must replace @IFN, and the DLCI number to be
monitored must replace @DLCI.
Example: frCircuitSentFrames
Change "1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI"
to "1.3.6.1.2.1.10.32.2.1.6.101015001.301"
The only valid interface number for a FrameSaver SLV 9126, 9126-II, 9126-II
Router, or 9128-II is 101015001.
4. Edit the new file, as needed.
Appendix B, SNMP MIBs and Traps, and RMON Alarm Defaults
September 2002
, for OID
9128-A2-GB20-80

Hide quick links:

Advertisement

Table of Contents
loading