Paradyne 9126 User Manual page 276

Paradyne router user's guide
Table of Contents

Advertisement

8. Troubleshooting
Table 8-1.
8-12
Alarm Conditions (6 of 7)
Alarm Condition
What It Indicates
Secondary Clock
A failure of the configured
Failed
secondary clock source for
the unit was detected and
the internal clock is
providing the timing for the
unit.
The clock source will not
automatically switch from
internal until the primary
clock source returns.
Self-Test Failure
The unit did not pass its
basic verification tests when
it was powered on or reset.
SLV Latency
The measured latency of
Exceeded, DLCI nnnn ,
SLV communication
1, 2, 3
frame relay link
responses from the remote
unit on this DLCI is
excessive, so the DLCI has
been declared unsuitable
for normal multiplexed PVC
operation (DLCI Type is set
to Multiplexed).
SLV Timeout, DLCI
An excessive number of
nnnn , frame relay
SLV communication
1, 2, 3
link
responses from the remote
system have been missed
on the specified multiplexed
DLCI and link.
If the frame relay link is
Net1-FR1, the timeout is on
the network FrameRly1
timeslot assignment.
When a hardware bypass-
capable device has been
detected at the other end of
the PVC and this condition
occurs, only user data for
EDLCI 0 will be transmitted
as long as the condition
exists.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port- n . The frame relay link associated with a user data port.
– ISDN Link Name on a non-network ISDN DBM interface.
3
Does not apply to a TS Access Management Link DLCI.
September 2002
What To Do
T
Reset the unit.
T
Contact your service
representative.
Wait until the DLCI is declared
operational again.
If the unit has ISDN backup
capability, this condition will
initiate backup.
T
Verify that the network LMI is
up. If it is, contact your network
service provider.
T
If a DBM is present and Auto
Backup is enabled, backup is
initiated automatically.
9128-A2-GB20-80

Hide quick links:

Advertisement

Table of Contents
loading