Technical data
8.3 Brake control
8.3
Brake control
Brake version
Rated operating voltage
Output voltage
Shutdown delay
Continuous current
Voltage drop during continuous current
Inrush current at t < 120 ms
Switching capacity to IEC60947-5-1
- AC 15, at 400 V AC
- DC 13, at 180 V DC
Fault message with non-controlled brake
Protective measures
Short-circuit protection
Inductive interference protection
Max. energy absorption of switching voltage limit
8.4
Inputs
Input characteristic to IEC60947-1 Appendix S and
IEC61131-2
Input voltage
Input current for signal "1"
Connection of 2-wire BEROs
Permissible residual current
Input signal delay
Supply from U
AS-i
Sensor supply
Total current sensor supply
Connection
Assignment of inputs
IN1
IN2
IN3
IN4
1)
Slave 2
2)
Slave 1
146
- Rated value
- for signal "0"
- for signal "1"
400 V AC / 230 V
AC 220 ... 600 V (-10% / +5%), 50 / 60 Hz
-
-
< 0.5 A
7 V
< 5 A
0.4 A
-
No
Yes, 1 A melting fuse
Integrated varistors
Type 1
24 V DC
-3 to +5 V
11 to 30 V
7 mA, typ.
Possible
1.5 mA, max.
10 ms to 80 ms, can be parameterized
Short-circuit and overload proof
16.5 to 30 V DC
Max. 200 mA (sensor supply is short-circuit proof)
M12 connector (A-coded)
Input 1 (DI2)
1)
Input 2 (DI3)
1)
Input 3 (DI0)
2)
Input 4 (DI1)
2)
Manual, 08/2014, A5E02548958A/RS-AA/004
180 V DC
0.45 x U
e. g.
e
180 V DC at 400 V AC
215 V DC at 480 V AC
50 ms
< 0.8 A
3.5 V
< 5 A
-
0.8 A
> 43 J (for 2 ms)
M200D AS-Interface Standard