8.3 Brake control

Note
Electromagnetic compatibility with pulse-shaped disturbance variables
With surges, you require a lightning protection element on the 24 V power supply. (see DP
master manual and description of SIMATIC NET PROFIBUS networks)
Note
To change the direction of rotation, a mechanically-switching reversing contactor is
integrated in reversing starters with solid-state switching. The preferred position of this
contactor is "CW rotation". When the direction is changed to "CCW rotation", the reversing
contactor is activated first, followed by the electronic contacts after an 80 ms delay.
8.3
Brake control
Brake version
Rated operating voltage
Output voltage
Shutdown delay
Continuous current
Voltage drop during continuous current
Inrush current at t < 120 ms
Switching capacity to IEC60947-5-1
- AC 15, at 400 V AC
- DC 13, at 180 V DC
Fault message with non-controlled brake
Protective measures
Short-circuit protection
Inductive interference protection
Max. energy absorption of switching voltage limit
172
400 V AC / 230 V
AC 220 ... 600 V (-10% / +5%), 50 / 60 Hz
-
-
< 0.5 A
7 V
< 5 A
0.4 A
-
No
Yes, 1 A melting fuse
Integrated varistors
Manual, 08/2014, A5E01577426A/RS-AA/004
180 V DC
0.45 x U
e. g.
e
180 V DC at 400 V AC
215 V DC at 480 V AC
50 ms
< 0.8 A
3.5 V
< 5 A
-
0.8 A
> 43 J (for 2 ms)
M200D PROFIBUS/PROFINET