Dedicated Baud Rate Generator - NEC 78K0S/KA1+ User Manual

8-bit single-chip microcontrollers
Hide thumbs Also See for 78K0S/KA1+:
Table of Contents

Advertisement

11.4.3 Dedicated baud rate generator

The dedicated baud rate generator consists of a source clock selector and an 8-bit programmable counter, and
generates a serial clock for transmission/reception of UART6.
Separate 8-bit counters are provided for transmission and reception.
(1) Configuration of baud rate generator
• Base clock
The clock selected by bits 3 to 0 (TPS63 to TPS60) of clock selection register 6 (CKSR6) is supplied to
each module when bit 7 (POWER6) of asynchronous serial interface operation mode register 6 (ASIM6) is
1. This clock is called the base clock and its frequency is called f
when POWER6 = 0.
• Transmission counter
This counter stops operation, cleared to 0, when bit 7 (POWER6) or bit 6 (TXE6) of asynchronous serial
interface operation mode register 6 (ASIM6) is 0.
It starts counting when POWER6 = 1 and TXE6 = 1.
The counter is cleared to 0 when the first data transmitted is written to transmit buffer register 6 (TXB6).
If data are continuously transmitted, the counter is cleared to 0 again when one frame of data has been
completely transmitted. If there is no data to be transmitted next, the counter is not cleared to 0 and continues
counting until POWER6 or TXE6 is cleared to 0.
• Reception counter
This counter stops operation, cleared to 0, when bit 7 (POWER6) or bit 5 (RXE6) of asynchronous serial
interface operation mode register 6 (ASIM6) is 0.
It starts counting when the start bit has been detected.
The counter stops operation after one frame has been received, until the next start bit is detected.
CHAPTER 11 SERIAL INTERFACE UART6
User's Manual U16898EJ3V0UD
. The base clock is fixed to low level
XCLK6
207

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents