NEC 78K0S/KA1+ User Manual page 212

8-bit single-chip microcontrollers
Hide thumbs Also See for 78K0S/KA1+:
Table of Contents

Advertisement

Minimum permissible data frame length: FLmin = 11 × FL −
Therefore, the maximum receivable baud rate at the transmission destination is as follows.
BRmax = (FLmin/11)
Similarly, the maximum permissible data frame length can be calculated as follows.
10
× FLmax = 11 × FL −
11
21k – 2
FLmax =
20k
Therefore, the minimum receivable baud rate at the transmission destination is as follows.
BRmin = (FLmax/11)
The permissible baud rate error between UART6 and the transmission destination can be calculated from the
above minimum and maximum baud rate expressions, as follows.
Table 11-5. Maximum/Minimum Permissible Baud Rate Error
Division Ratio (k)
8
20
50
100
255
Remarks 1. The permissible error of reception depends on the number of bits in one frame, input clock
frequency, and division ratio (k). The higher the input clock frequency and the higher the division
ratio (k), the higher the permissible error.
2. k: Set value of BRGC6
212
CHAPTER 11 SERIAL INTERFACE UART6
22k
− 1
=
Brate
21k + 2
21k − 2
k + 2
× FL =
FL
2 × k
2 × k
FL × 11
20k
− 1
=
Brate
21k − 2
Maximum Permissible Baud Rate Error
+3.53%
+4.26%
+4.56%
+4.66%
+4.72%
User's Manual U16898EJ3V0UD
k − 2
21k + 2
× FL =
FL
2k
2k
Minimum Permissible Baud Rate Error
−3.61%
−4.31%
−4.58%
−4.67%
−4.73%