Builder, Configuration Mode
Field
Option
<Auto Off:>
Enable
Disable
<Measure&
Record:>
MEAS/REC
ALL-in-1
Description
1
No beep
2
Fast beep, interrupted; from 95.0 to 99.5 gon
and 105.0 to 100.5 gon
3
Permanent beep; from 99.5 to 99.995 gon and
from 100.5 to 100.005 gon
Sets the behaviour of power down and instrument.
The instrument is turned off after 20 minutes without
any action, for example no key pressed;
Vertical and horizontal angle deviation is
The instrument is turned on permanently.
Battery discharges quicker.
Assigns seperated or combined measurement func-
tionality to middle softkey button in all measure
screens.
Starts distance and angle measurements without
saving measured values. After measurement displayed
values can be saved with RECORD.
Starts distance and angle measurements and saves
measured values in one step.