Combined adjust-
ment procedure
step-by-step
Builder, Check & Adjust
The following table explains the most common settings. Refer to the stated chapter
for more information on screens.
1. Turn on the instrument by pressing the
2. Level up the instrument.
Refer to "5.2 Instrument Setup" for more information.
3. Make sure that THEO mode is active.
4. Press
for approximately 5 seconds until SYSTEM INFO is active.
5. Press CALIBR.
6. Press NEW.
7.
± 5°
8. Press MEASURE to measure the target
key.
Aim with the telescope accurately at a
target at a distance of about 100 m. The
target must be positioned within ± 5° of the
horizontal plane.
183