Builder, Configuration Mode
Standard RS232
Field
Option
Databits
7
8
Parity
None, Even or
Odd
Endmark
CR/LF
CR
Stopbits
1
Bluetooth
PIN
Standard RS232 is supported by default.
Field
Baudrate
Description
Number of bits in a block of digital data.
Set automatically if <Parity:> Even or Odd.
Set automatically if <Parity:> None.
Error checksum at the end of a block of digital
data.
The terminator is a carriage return followed by
a linefeed.
The terminator is a carriage return.
Number of bits at the end of a block of digital
data.
Set user-defined Bluetooth PIN with 4 charac-
ters. 0000 is set by default.
Option
38400 for Builder 200
57600 for Builder 300
115200 for Builder 400 and 500