10.2 Status Messages; Using The Xe Edp Command - Rice Lake IQ plus 710 Installation Manual

Digital weight indicator
Hide thumbs Also See for IQ plus 710:
Table of Contents

Advertisement

10.1.2

Using the XE EDP Command

The XE EDP command can be used to remotely query
the IQ plus 710 for the error conditions shown on the
front panel. The XE command returns a decimal
number representing any existing error conditions.
If more than one error condition exists, the number
returned is the sum of the values representing the error
conditions (see Table 10-2). For example, if the XE
command returns the number 1040, this value
represents the sum of an A/D reference error (1024)
and an A/D calibration checksum error (16).
Error
Discontinued Product
Code
Description
0
No error
1
EEPROM physical error
2
Virgin EEPROM
4
Parameter checksum error
8
Load cell calibration
checksum error
16
A/D calibration checksum
error
32
Print format checksum
error
64
Internal RAM data error
128
External RAM data error
256
NV register checksum error 0000 0001 0000 0000
512
A/D physical error
1024
A/D reference error
2048
Tare register error
4096
Accumulator overflow error
8192
A/D underrange
16384 Power failure
32768 Gross > overload limit
Table 10-2. Error Codes Returned on XE Command
66
IQ plus 710 Installation Manual

10.2 Status Messages

Two EDP commands, P and ZZ, can be used to
provide status about the indicator.
Binary Value
0000 0000 0000 0000
0000 0000 0000 0001
0000 0000 0000 0010
0000 0000 0000 0100
0000 0000 0000 1000
0000 0000 0001 0000
If the indicator is in an underrange or overload
condition, the weight value is replaced with
0000 0000 0010 0000
&&&&&&
0000 0000 0100 0000
0000 0000 1000 0000
0000 0010 0000 0000
0000 0100 0000 0000
0000 1000 0000 0000
0001 0000 0000 0000
0010 0000 0000 0000
0100 0000 0000 0000
1000 0000 0000 0000
The P EDP command returns whatever is
currently shown in the indicator's primary
display area.
The ZZ EDP command returns whatever is
currently shown in both the primary and
secondary displays. Depending on the type of
device used to receive data from the indicator,
the standstill and center of zero symbols may
be shown as spaces or as special characters.
The ZZ command returns information in the
following format:
PPPPPPP uu ssssssssssssssss
where:
is the information shown on the
PPPPPPP
primary display
is the 2-digit units annunciator
uu
is the contents of the
ssssssssssssssss
secondary display
(overload) or
::::::
(underrange).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents