8.0

Setpoints

The IQ Plus 710 indicator provides twenty programmable setpoints for control of both indicator and external
equipment functions. Setpoints are configured to trip based on specified conditions; tripping the setpoint can be
used to request indicator functions (print, tare, accumulate) or to change the state of a digital output controlling
external equipment.
NOTE: Weight-based setpoints are tripped by values specified in primary units only.
Figure 8-1 shows the general structure of the SETPTS menu. See Section 3.2.7 on page 29 for a detailed
description of the SETPTS menu. The eighteen setpoint kinds are described in Table 8-1 on page 56.
CONFIG
FORMAT
CALIBR
Discontinued Product
SP CFG
SETPT1
OFF
GROSSSP
NETSP
COUNTER
AUTOJOG
TIMER
CONCUR
8.1

Batch and Continuous Setpoints

IQ Plus 710 setpoints can be either continuous or batch setpoints.
Continuous setpoints
value at each A/D update. If the input channel weight reading matches the setpoint value, the indicator sets
the corresponding digital output on.
are active one at a time, in an ordered sequence. The
Batch setpoints
up to twenty separate batch processing steps. A digital output associated with a batch setpoint is on until the
setpoint condition is met, then latched for the remainder of the batch sequence.
To use batch setpoints, you must activate the BATCHNG parameter on the SETPTS menu. This parameter
defines whether a batch sequence is automatic or manual. AUTO sequences repeat continuously, while
MANUAL sequences require a BATSTRT digital input, BATSTART EDP command, or STRTBAT macro
command before restarting. As shown in Table 8-1 on page 56, GROSSSP, NETSP, and RELSP setpoint kinds
can be configured as either batch or continuous setpoints.
The BATCH parameter must also be set on for each batch setpoint. If the setpoint is defined but the BATCH
parameter is off, the setpoint operates as a continuous setpoint, even during batch sequences.
SERIAL
PROGRM
SETPT2 – SETPT20
Same as SETPT1
+RELSP
–RELSP
COZ
INMOTON
Figure 8-1. SETPTS Menu
are free-running: the indicator constantly checks the input channel for the setpoint
PFORMT
SETPTS
DIG IN
BATCHNG
AUTO
MANUAL
%RELSP
PAUSE
INRANGE
–GROSS
920i
can use batch setpoints to control
XXXXXXX
ALGOUT
VERS
OFF
DELAY
WAITSS
–NET
BATCHPR