1.8

Rate Of Change

Rate of change is expressed in weight per time unit (weight/time).
Example: lb/sec
See the 1280 Technical Manual for information on how to enable rate of change.
To view the rate of change:
1. Press the
Display Rate of Change
2. To return to the live weight, press
1.9

Setpoint Entry

Setpoints can be configured to perform actions or functions based on specified parameter conditions. For more
information on setpoints, see the 1280 Technical Manual.
To change the setpoint value:
1. Press
.
Setup
2. Press the
Setpoint Values
3. Press
to select the setpoint (1-100) for which the target value needs to be changed.
Setpoint 1
4. Press the red number of the setpoint in the table. It may be necessary to use the arrows at the bottom of the
screen scroll through the setpoints.
5. Press
to bring up the numeric entry keypad.
Value
6. Enter the new target value and press
7. Press
to toggle between enabled and disabled.
Settings
8. Press
and
Done
Save and Exit

1.10 Softkey Operations

Softkeys are configured to provide additional operator functions. Softkeys are displayed as digital buttons at the
bottom of the touch screen display area. See Figure 1-1 on page 3.
See the 1280 Technical Manual for softkey configuration.
Softkey
Blank
Inserts a blank key between assigned softkeys.
Time/Date
Allows time and date change.
Display Tare
Displays a tare value for the current scale.
Display Accum
Displays an accumulator value, if enabled, for the current scale.
Display ROC
Displays a rate-of-change value, if enabled, for the current scale.
Setpoint
Displays a list of configured setpoints; allows change to target and enable parameters.
Batch Start
Starts a configured batch.
Batch Stop
Stops a running batch and turns off all associated digital outputs. Requires a batch start to resume processing.
Batch Pause
Pauses a running batch, deactivating current batch digital outputs except those associated with concurrent and
timer setpoints. A batch start is required to to resume the batch.
Batch Reset
Stops a batch and resets it to the first batch step.
Unit ID
Displays the name given to the 1280.
Scale Select
Prompts for the scale number desired for multi-scale applications.
Diagnostics
Future sofkey
Alibi
Previous print transactions can be recalled and reprinted.
Contrast
Adjusts the screen's backlight if set to manual.
Stop
Sends AuxFmt13 out a configured port to prompt a red light on a LaserLight.
Go
Sends AuxFmt12 out a configured port to prompt a green light on a LaserLight.
Off
Sends AuxFmt14 out a configured port to turn a LaserLight red/green light off.
Screen
Allows multiple display screens without a user program.
F1–F10
These are user-programmable keys; defined by application.
< or >
For applications with more than five defined softkeys, the < or > softkeys are automatically assigned to the fifth
softkey position. If there are more keys to the right the > softkey will appear, if there are more keys to the left, the
< softkey will appear. Press < or > to toggle between groups of softkeys.
10
1280 Enterprise Series
softkey.
Display Rate of Change
key in the Main menu or from the black drop down list, or press the
.
Done
.
Table 1-4. Configurable Softkeys
again.
Description
softkey.
Setpoint

Advertisement

Table of Contents
loading

Table of Contents