10.3 Tare And Zero Key Functions - Rice Lake IQ plus 710 Installation Manual

Digital weight indicator
Hide thumbs Also See for IQ plus 710:
Table of Contents

Advertisement

10.3 TARE and ZERO Key Functions

The function of the front panel TARE and ZERO keys depends on the value specified for the REGULAT
parameter on the PROGRM menu. Table 10-3 describes the function of these keys for each of the regulatory
modes.
REGULAT
Parameter Value
NTEP
Discontinued Product
CANADA
OIML
NONE
Table 10-3. TARE and ZERO Key Functions for REGULAT Parameter Settings
Weight on Scale
Tare in System
zero or negative
positive
zero or negative
positive
zero or negative
positive
zero or negative
positive
Front Panel Key Function
TARE
no
no action
yes
CLEAR TARE
no
TARE
yes
TARE
no
no action
yes
CLEAR TARE
no
TARE
yes
no action
no
no action
yes
CLEAR TARE
no
TARE
yes
TARE
no
TARE
yes
CLEAR TARE
no
TARE
yes
CLEAR TARE
ZERO
ZERO
ZERO
ZERO
ZERO and CLEAR TARE
ZERO
no action
ZERO
Appendix
67