SETPTS Menu
Parameter
Choices
PREACT
OFF
ON
LEARN
PREVAL
number
Discontinued Product
RELNUM
1–20
BATCH
OFF
ON
PSHACCM
OFF
ON
ONQUIET
PSHPRNT
OFF
ON
WAITSS
PSHTARE
OFF
ON
ALARM
OFF
ON
START
1–20
END
1–20
ACCESS
ON
HIDE
OFF
GROSSSP, NETSP, and RELSP setpoint types: Allows the digital output associated
with a setpoint to shut off before the setpoint is satisfied to allow for material in
suspension.
The ON value adjusts the setpoint trip value up or down (depending on the TRIP
parameter setting) from the setpoint value.
The LEARN value can be used to automatically adjust the preact value after each
batch. LEARN compares the actual weight at standstill to the target setpoint value,
then adjusts the preact by half of the difference after each batch.
GROSSSP, NETSP, and RELSP setpoint types: Specifies the preact value for
setpoints with PREACT set to ON or LEARN. Depending on the TRIP setting
specified for the setpoint, the setpoint trip value is adjusted up or down by the preact
value.
RELSP setpoints: Specifies the number of the relative setpoint. The target weight for
this setpoint is:
• For +RELSP, the value of the relative setpoint plus the value (VALUE parameter) of
this setpoint
• For –RELSP, the value of the relative setpoint minus the value of this setpoint
• For %RELSP, the percentage (specified on the VALUE parameter for this setpoint)
of the relative setpoint
GROSSSP, NETSP, and RELSP setpoint types: Specifies whether the setpoint is
used as a batch (ON) or continuous (OFF) setpoint.
GROSSSP, NETSP, RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify ON
to update the accumulator and perform a print operation when the setpoint is
satisfied. Specify ONQUIET to update the accumulator without printing. Gross weight
must return to zero before another accumulation can occur.
GROSSSP, NETSP, RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify ON
to perform a print operation when the setpoint is satisfied; specify WAITSS to wait for
standstill after setpoint is satisfied before printing.
GROSSSP, NETSP, RELSP, PAUSE, DELAY, and WAITSS setpoint types: Specify ON
to perform an acquire tare operation when the setpoint is satisfied. NOTE: PSHTARE
acquires the tare regardless of the value specified for the REGULAT parameter on the
PROGRM menu.
GROSSSP, NETSP, RELSP, DELAY, and WAITSS setpoint types: Specify ON to
display the word ALARM on the primary display while the setpoint is active (batch
setpoints) or while the setpoint is not tripped (continuous setpoints).
TIMER and CONCUR setpoint types: Specifies the starting setpoint number. Do not
specify the number of the TIMER or CONCUR setpoint itself. The TIMER or
CONCUR setpoint begins when the starting setpoint begins.
TIMER and CONCUR setpoint types: Specifies the ending setpoint number. Do not
specify the number of the TIMER or CONCUR setpoint itself. The TIMER or
CONCUR setpoint stops when the ending setpoint begins.
All setpoint types: Specifies whether the SETPOINT key can be used to change the
setpoint value in normal mode, including macro simulations of pressing the
SETPOINT key.
ON: Value can be displayed and changed
HIDE: Value cannot be displayed or changed
OFF: Value can be displayed but not changed
Setpoints with ACCESS=ON can be turned on or off when a batch is not running:
To turn the setpoint off, display the setpoint, then press CLEAR
To turn the setpoint on, display the setpoint, then press ENTER