8.2.2

Example 2

The following example uses seven setpoints to control
a two-speed fill operation where both fast and slow
feeds are on simultaneously.
Digital inputs 1 and 2 are assigned to batch start and
batch run functions: BATRUN must be on (low)
before the BATSTRT input starts the batch.
DIGIN1=BATSTRT
DIGIN2=BATRUN
BATCHNG=MANUAL
Setpoint 1 ensures that the scale is empty (0±2
Discontinued Product
SETPOINT=1
KIND=GROSSSP
VALUE=0
TRIP=INBAND
BANDVAL=2
BATCH=ON
Setpoint 2 checks for the weight of a container (Š 5
) placed on the scale.
LB
SETPOINT=2
KIND=GROSSSP
VALUE=5
TRIP=HIGHER
BATCH=ON
Setpoint 3 waits for standstill, then tares the container
weight, placing the indicator in net mode.
SETPOINT=3
KIND=WAITSS
PSHTARE=ON
Setpoint 4 starts the fast fill operation. When the net
weight reaches 175
, the setpoint trips and digital
LB
output 1 is set off.
SETPOINT=4
KIND=NETSP
VALUE=175
TRIP=HIGHER
BATCH=ON
DIGOUT=1
58
IQ Plus 710 Installation Manual
Setpoint 5 controls the slow fill operation. When the
net weight reaches 200
(see Setpoint 7), the indicator waits for standstill and
performs a push print operation using the SPFMT
ticket format.
SETPOINT=5
KIND=NETSP
VALUE=200
PSHPRINT=WAITSS
TRIP=HIGHER
BATCH=ON
DIGOUT=2
).
LB
Setpoint 6 is a continuous setpoint, used to allow the
slow feed output to be on at the same time as the fast
fill. The slow fill output (digital output 2) is turned on
when setpoint 4 (fast fill) starts and remains on until
setpoint 5 begins.
SETPOINT=6
KIND=CONCUR
VALUE=0
START=4
END=5
DIGOUT=2
, the slow fill is stopped
LB