Rice Lake IQ plus 710 Installation Manual page 30

Digital weight indicator
Hide thumbs Also See for IQ plus 710:
Table of Contents

Advertisement

PROGRM Menu
Parameter
Choices
Level 2 submenus
DATE
DATEFMT
DATESEP
TIME
TIMEFMT
TIMESEP
Discontinued Product
CONSNUM
0
number
CONSTUP
0
number
UID
0
unit-ID
TARE100
OFF
MODE1
MODE2
MODE3
MODE4
MODE5
MODE6
ACCUM
OFF
ON
CFGPWD
0
1–9999999
SPPWD
0
1–9999999
KYBDLK
OFF
ON
NOTE: No more than one of the AUXLK, MACONLY, and ZERONLY parameters can be specified as ON. Individual keys can be
locked or unlocked using the KLOCK and KUNLOCK EDP commands (see Table 5-1 on page 41 for more information).
AUXLK
OFF
ON
MACONLY
OFF
ON
ZERONLY
OFF
ON
ALPHAKB
ON
OFF
26
IQ plus 710 Installation Manual
Allows selection of date format and date separator character. See Level 3 submenu parameter
descriptions.
Use the TIME/DATE key or the SD EDP command to set the date. See Section 5.0 on page 41
for information about using the EDP commands.
Allows selection of time format and separator character. See Level 3 submenu parameter
descriptions.
Use the TIME/DATE key or the ST EDP command to set the time. See Section 5.0 on page 41
for information about using the EDP commands.
Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation that includes <CN> in the ticket
format. When the consecutive number is reset, it is reset to the value specified on the
CONSTUP parameter.
Specifies the consecutive number start-up value used when the consecutive number is reset
by sending the KCLRCN EDP command or a CLRCN digital input. Value specified must be in
the range 0–9 999 999.
Specifies the unit identification number. Value specified can be any alphanumeric value, up to
seven characters.
Specifies the truck mode used. If selected, the indicator switches from normal mode to the
selected truck mode. See Section 7.0 on page 53 for more information about using the truck
modes.
MODE1: Auto clear ID, keyed tares, value swapping
MODE2: Auto clear ID, no keyed tares, value swapping
MODE3: Stored ID, keyed tares, value swapping
MODE4: Stored ID, no keyed tares, value swapping
MODE5: Stored ID, keyed tares, no value swapping
MODE6: Stored ID, no keyed tares, no value swapping
Accumulator. Specifies whether the accumulator is enabled.
Configuration password. Specify a non-zero value to restrict access to all configuration menus.
Setpoint password. Specify a non-zero value to restrict access to the setpoint menu.
Keyboard lock. Specify ON to disable the keypad in normal mode.
Auxiliary keypad lock. Specify ON to disable all keys except ZERO, GROSS/NET, TARE,
UNITS, and PRINT in normal mode. See NOTE above.
Macro keys only. Specify ON to disable all except the four macro keys (F1–F4) in normal mode.
See NOTE above
Zero key only. Specify ON to disable all front panel keys except ZERO in normal mode. See
NOTE above
Alpha keyboard. Specify ON to enable alpha entry for the indicator keypad. If OFF is specified,
the ALPHA ENTRY key is disabled.
Table 3-6. Program Menu Parameters
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents