3.2.9

Analog Output Menu

The ALGOUT menu is used only if the analog output option is installed. If the analog output option is installed,
configure all other indicator functions and calibrate the indicator before configuring the analog output. See
Section 10.7 on page 71 for analog output calibration procedures.
CONFIG
XXXXXXX
FORMAT
CALIBR
SOURCE
OFFSET
0%
GROSS
20%
NET
Discontinued Product
ALG OUT Menu
Parameter
Choices
Level 2 submenus
SOURCE1
GROSS
NET
OFFSET
0%
20%
ERRACT
FULLSC
HOLD
ZEROSC
MIN
000000
number
MAX
010000
number
TWZERO
71
number
TWSPAN
15171
number
3.2.10

Version Menu

The VERS menu is used to check the software version installed in the indicator. There are no parameters
associated with the Version menu: when selected, the indicator displays the installed software version number.
CONFIG
FORMAT
XXXXXXX
36
IQ plus 710 Installation Manual
SERIAL
PROGRM
ERRACT
FULLSC
HOLD
ZEROSC
Figure 3-16. Analog Output Menu
Specifies the source tracked by the analog output.
Zero offset. Selects whether the analog output supplies voltage (0–10 V) or current (4–20 mA)
output. Select 0% for 0–10 V output; select 20% for 4–20 mA output.
Error action. Specifies how the analog output responds to system error conditions.
Possible values are:
FULLSC: Set to full value (10 V or 20 mA)
HOLD: Hold current value
ZEROSC: Set to zero value (0 V or 4 mA)
Specifies the minimum weight value tracked by the analog output. Specify a value in the range
0–9999999.
Specifies the maximum weight value tracked by the analog output. Specify a value in the range
0–9999999
Tweak zero. Adjust the analog output zero calibration. Use a multimeter to monitor the analog
output value. Press and hold
Tweak span. Adjust the analog output span calibration. Use a multimeter to monitor the analog
output value. Press and hold
Table 3-8. Analog Output Menu Parameters
CALIBR
SERIAL
PROGRM
Figure 3-17. Version Menu
PFORMT
XXXXXXX
SETPTS
XXXXXXX
DIG IN
MIN
MAX
000000
10000
number
number
Description
or
to adjust the output.
or