    1280 Enterprise Series™ Color Touchscreen Indicator Operation Manual PN 166046...
  • Page 3: Table Of Contents

    Course descriptions and dates can be viewed at www.ricelake.com/training or obtained by calling 715-234-9171 and asking for the training department. © Rice Lake Weighing Systems. All rights reserved. Printed in the United States of America. Specifications subject to change without notice.
  • Page 4 Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost. Visit www.ricelake.com/webinars 1280 Enterprise Series...
  • Page 5: Introduction

    1280 delivers uncompromising speed for today’s most demanding applications as well as vast expandability for future needs. Manuals can be viewed or downloaded from the Rice Lake Weighing Systems website at www.ricelake.com/manuals Warranty information can be found on the website at www.ricelake.com/warranties...
  • Page 6: Safety

    Do not operate or work on this equipment unless you have read and understood the instructions and warnings in this manual. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement manuals. Proper care is your responsibility.
  • Page 7: Weighing Mode

    Weighing Mode Figure 1-1. Weighing Mode Display Screen Item No. Description Status Bar Menu key – Press to enter setup menus and audit trail information. Current time – Press to set the time. Current date – Press to set the date. Scale arrows –...
  • Page 8: Numeric/Alpha Entry

    Item No. Description Cancel - Press to exit keyboard. Done - Press to complete keyboard entry. Clear - Delete everything in the prompt line. Backspace - Delete one character at a time. Table 1-2. On-screen Keyboard Descriptions 1280 Enterprise Series...
  • Page 9: Indicator Operations

    Indicator Operations Display/Touchscreen Numeric Keypad Navigation Keys Figure 1-4. 1280 Front Panel 1.4.1 Navigation Keys Navigation keys are primarily linked to iRite handlers. If no iRite handlers exist, the navigation keys toggle through a selection of displayed scales. 1.4.2 Numeric Keypad Use the numeric keypad for entering numbers or keyed tares.
  • Page 10: Tare

    • A softkey can be programmed for each function • A can be activated Display Clear Accumulator Digital Input • A serial command can be sent Print the Accumulated Value To print the accumulated value, press while displaying the accumulator. 1280 Enterprise Series...
  • Page 11: Setup Menu

    Setup Menu Press on the Weigh mode screen. The will display. Main Menu Press to return to the Weigh mode. Figure 1-5. Main Menu Screen Item Description Configuration – Allows setup of indicator parameters. See the 1280 Technical Manual. Calibration – Allows calibration of the scale. See the 1280 Technical Manual. Setpoint Values –...
  • Page 12: Audit Trail

    (default is port 1). See the 1280 Technical Manual for port setup, including how to change the destination or baud rate of the audit trail ticket format. 2. Select to return to the weigh mode. 1280 Enterprise Series...
  • Page 13: Language

    1.5.2 Language From the Main menu, press to select one of the 16 language choices. The set language is only available in weigh mode. Configuration mode will remain in English. 1. Press to display the list of available languages. 2. Select the desired language. 3.
  • Page 14: Rate Of Change

    If there are more keys to the right the > softkey will appear, if there are more keys to the left, the < softkey will appear. Press < or > to toggle between groups of softkeys. Table 1-4. Configurable Softkeys 1280 Enterprise Series...
  • Page 15: 1.11 Applications

    1.11 Applications The 1280 can be used in a variety of applications, including checkweighing, counting, recipe batching and truck in/out. For these frequently used applications, the 1280 includes built-in programs that can be used as-is or customized for specific needs. See the 1280 Technical Manual for more information on importing and exporting built-in application programs.
  • Page 16: Counting Application

    Tare weight to net zero, and then the count pieces were removed, the scale would display a negative number. Gross: 10.25 lb APW: .0055 lb Pieces: 1864 1/1/2015 01:00 PM Figure 1-9. Counting Printed Ticket Example 1280 Enterprise Series...
  • Page 17: Recipe Batching Application

    Application Setup and Configuration Parameter Default Softkey Description System Time and Current Time/Date Time and Date of that displays on the 1280. Date System Password “” Setup Password Allows an operator to change the password that is required for entry into the Setup Menu.
  • Page 18: Truck In/Out Application

    The softkeys (requires Weigh In Weigh Out Truck Register Toggle Light Stop and Go Laserlight, sold separately) display on the indicator. Slot 0 Output Bit 1 Green Bit 2 Table 1-9. LaserLight Output 1280 Enterprise Series...
  • Page 19 Weigh In 1. Press the softkey. displays. Weigh In Enter Truck ID 2. Enter the Truck ID. 3. Press Enter • If the ID is found, the indicator displays . Return to step 1. Truck Already Weighed In • If the ID is not found, the scale captures a gross weight, adds the inbound transaction to the truck register, prints a weigh ticket and displays .
  • Page 20 Threshold Weight 5000 Threshold Weight Enter the weight that triggers the optional traffic light. The weight must go above/below the threshold weight between weighments. Table 1-10. Truck In/Out Application Setup and Configuration 1280 Enterprise Series...
  • Page 21: Specifications

    Specifications Power AC Digital I/O Line Voltages 85-265 VAC 8 channels Configurable as inputs or outputs Frequency 50 or 60 Hz Inputs 5 VDC max, active low Power Consumption 60 Watts Outputs 20 mA max per channel, active low 5 VDC source available - 500 mA max Power DC Line Voltages 9-36 VDC...
  • Page 22 1280 Enterprise Series...
  • Page 24 Specifications subject to change without notice. Rice Lake Weighing Systems is an ISO 9001 registered company. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319 www.ricelake.com www.ricelake.mx www.ricelake.eu www.ricelake.co.in...